ES622 Series TLP Pulsed IV-Curve System

ES622 Series TLP Pulsed IV-Curve System is an advanced IV-curve characterization system designed to simulate ESD events (TLP/ VF-TLP/ HMM/ HBM/MM pulse) and monitor a device

  • 產(chǎn)品型號:ES622-50
  • 廠商性質(zhì):代理商
  • 更新時間:2024-08-21
  • 訪  問  量:949
立即咨詢

聯(lián)系電話:0731-85782021

詳細(xì)介紹

ES622 Series TLP Pulsed IV-Curve System


1.    Description

The model ES622 Series TLP Pulsed IV-Curve System is an advanced IV-curve characterization system designed to simulate ESD events (TLP/ VF-TLP/ HMM/ HBM/MM pulse) and monitor a device (semiconductors, discrete, circuit modules, etc.) in high power time domain. The ES622 has a higher specification, more functionality, greater expansion capability and better software experience compared to the previous model ES620 and ES621.

The TLP (transmission line pulse) test function is designed to meet the latest ANSI/ESD STM5.5.1 test standard and applies high quality rectangular pulses to devices and records both the voltage across and current through the device. This gives pulsed IV curves, allowing users to characterize a device’s transient response over ns time windows. Advanced automatic device failure detection methods are incorporated, such as DC Spot Check (V or I), Static IV curve, Fuse, Breakdown, and Bias Source Fluctuation.

The VF-TLP test is designed to simulate the CDM speed ESD event and captures the voltage across the DUT and current through the DUT under a high speed (such as <100 ps rise-time) ESD transient. This allows the user to study the response speed and peak clamping voltage of a device.

The HMM (Human Metal Model) test function is an alternative test method to IEC61000-4-2 system level ESD. It gives the equivalent waveform to an ideal standard waveform for low ohm devices and eliminates many IEC gun test problems for components or wafer level tests, such as repeatability, imprecision gun tip, impedance mismatches, EMI interferences from unshielded relays and special setup with large ground plane and coupling plane etc.

2.    Features

  • Most configurable TLP Pulsed IV-Curve System

  • Ultra-Compact Design System

  • Fast test speed with multi-thread processing

  • 20 A, 40A, 50 A, 100 A, 125A, 150 A models are available (Customization available)

  • Advanced system and accessory monitor and control in software available
    (switch lifespan monitor, E-Cal module, oscilloscope attenuation adjustment)

  • Test Function Expandable with vf-TLP, CC-TLP, HMM, HBM, MM options

  • Multiple automatic failure detection methods
    (DC spot check (V or I) or IV sweep, fuse, breakdown, and bias current change)

  • Software controlled pulsing: Burst, Continuous, IV-Curve Characterization

  • Rise-Time options from 40 ps to 1200 ns *(depends on model, customization available)

  • Pulse-Width options from 1 ns to 2000 ns *(depends on model, customization available)

Note*: Longer pulse applications are supported by EOS series with pulse width from few hundred of ns to few ms.

3.     Applications

  • ESD performance characterization

  • Wafer/ package level ESD test

  • System / circuit module ESD test

  • Safe operation area (SOA) test

  • Charge recovery time test

  • Solar panel diode characterization

  • Touchscreen ITO trace fuse and breakdown test

Related Standards:

  • TLP / VF-TLP option meets ANSI/ESD STM 5.5.1

  • HMM option meets ANSI/ESD SP5.6

  • HBM option meets ANSI/ESDA/JEDEC JS-001

  • MM option meets ANSI/ESDA SP5.2

4.    Specifications

ES622 Series TLP Unit Specifications

Typical Models ES622-20 ES622-50 ES622-100 ES622-125 ES622-150 Unit *Special models such as 40, 100, 200+ A are available per request
Output voltage  @ Open load ± 0.5 ~ 1000 ± 0.5 ~ 2500 ± 0.5 ~ 5000 ± 0.5 ~ 6250 ± 0.5 ~ 7500 V  
Min Voltage step @ Open load 0.1 0.1 0.1 0.1 0.1 V  
Output current @ Short load ± 0.01 ~ 20 ± 0.01 ~ 50 ± 0.01 ~ 100 ± 0.01 ~ 125 ± 0.01 ~ 150 A  
Voltage precision Accuracy adjustable between 1 – 10 % % Speed / accuracy software adjustable
Fastest rise-time*
(default 20-80%)
≤ 50 ≤ 200 ≤ 300 ≤ 300 ≤ 300 ps Fastest 10-90% 40 ps risetime is available with special configuration
Rise-time range 0.05 ~ 1200 0.2 ~ 1200 0.3 ~ 1200 0.3 ~ 1200 0.3 ~ 1200 ns  
Rise-time options Unlimited programable or manual options   per customization
Pulse-width
(default 50-50%)
100 ± 1 ns Default
Min Pulse-width 0.5 1 5 5 5 ns  
Max Pulse-width 2000 2000 1500 1500 1000 ns  
Pulse-width options Unlimited programable or manual options   per customization
Test Speed Typical 0.2 ~ 2 Sec Varies between hardware setups
Dimensions 347 W X 300 D X 145 H mm May change per customization
Weight 8 8 8 10 12 kg  
Supported Oscilloscopes Major Series from Tektronix, Agilent, LeCroy, Rigol. Others supported on request
Supported SMU Keithley 24xx/26xx series SMU Others supported on request

ES62X-HMM2 External Human Metal Model (HMM) Module
(short circuit DUT, 100 ? HMM per ANSI/ESD SP5.6)

@ Typical Models ES620-20 ES620-50 ES622-100 ES620-125 ES620-150 Unit Comments
IEC equivalent level 6 12 24 30 36 kV  
HMM peak current 22.5 45 90 112.5 135 A 3.75 A per 1 kV ≤ ± 10 %

 

IEC 61000-4-2 (R=330?, C=150pF)

HMM current @ 30 ns 12 24 48 60 72 A ≤ ± 10 % (better than ±30% IEC)
HMM current @ 60 ns 6 12 24 30 36 A ≤ ± 10 % (better than ±30% IEC)

ES62X-HBM2 External Human Body Model (HBM) Module
(ANSI/ESDA/JEDEC JS-001 R=1.5 k?, C=100 pF)

@ Typical Models ES620-20 ES620-50 ES622-100 ES620-125 ES620-150 Unit Comments
Maximum HBM Test Level ± 2 ± 4 ± 8 ± 10 ± 12 kV  
Minimum HBM Test Level ± 50 V  
Minimum Test Level Step 1 V PCB controlled via USB
Charge Removal Resistance 10 K Ohm  
Test Speed >= 1 S Per Standard 1P/S
Physical Dimensions 90 X 90 X 130 mm  

ES62X-MM2 External Machine Model (MM) Module
(ANSI/ESDA/JEDEC JS-001 R=1.5 k?, C=100 pF)

Parameters MM-2K Unit Comments
Output Voltage ±10 ~ 2000 V  
Discharge RC Value C: 200 pF, R: 0 Ω    
Short Load Peak Current Ip1 1.75±10% per 100V A Tolerance may be different if socket is used
Short Load Ip2 67% ~ 90% of Ip1 A
Short Load Pulse Period tpm 66 < tpm < 90 ns
500 Ω Load Peak Current Ipr 0.85 ~ 1.2 A @ 400 V condition per standard
500 Ω Load I100 0.23 ~ 0.4 A @ 400 V condition per standard
500 Ω Load I200 30 – 50% of measured I100 A  

5.    Ordering Information

Line Part # or Option # Description
TLP IV-Curve System Basic Configuration
1.1 ES622-20 ES622 TLP Pulsed IV-Curve System, 20 A Base Unit
1.2 ES622-25 ES622 TLP Pulsed IV-Curve System, 25 A Base Unit
1.3 ES622-40 ES622 TLP Pulsed IV-Curve System, 40 A Base Unit
1.4 ES622-50 ES622 TLP Pulsed IV-Curve System, 50 A Base Unit
1.5 ES622-60 ES622 TLP Pulsed IV-Curve System, 50 A Base Unit
1.6 ES622-80 ES622 TLP Pulsed IV-Curve System, 80 A Base Unit
1.7 ES622-100 ES622 TLP Pulsed IV-Curve System, 100 A Base Unit
1.8 ES622-125 ES622 TLP Pulsed IV-Curve System, 125 A Base Unit
1.9 ES622-150 ES622 TLP Pulsed IV-Curve System, 150 A Base Unit
Rise-time Options (example configuration only, customizable option available)
2.1 ES62x-PRT4 Programmable pulse rise-time filter X4 module
(Default:   Intrinsic, 1 ns, 5 ns, 10 ns, customization available)
2.2 ES62x-PRT7 Programmable pulse rise-time filter X7 module
(Default:   Intrinsic, 0.5ns, 1 ns, 2ns, 5 ns, 10 ns, 20ns, customization available)
2.3 ES62x-ERTF External Manual Rise-time Filter
Pulse-width Options (example configuration only, customizable option available)
3.1 ES620-PPL4 ProgrammableInternal pulse length X4 module
(Default:   5ns, 10 ns, 100 ns, 200 ns, customization available)
  ES620-PPL7 ProgrammableInternal pulse length X7 module
(Default:   5ns, 10 ns, 50ns, 100 ns, 200 ns, 500ns, 1000ns, customization available)
3.2 ES620-PPL10 ProgrammableInternal pulse length X10 module
(Default:   2ns, 5ns, 10 ns, 20ns, 50ns, 100 ns, 200 ns, 500ns, 1000ns, 1500ns, customization available)
3.3 ES620-MPLEx Manual Pulse Width Extremal Change Option
ESD Injection and IV-Curve Measurement Options
4.1 ES62X-DBLM TLP Automatic Test Software with PC
4.2 ES62X-A1 TLP IV-Curve Test Essential Accessories
4.3 ES62X-BSA Board Level Standard TLP Test Accessories
4.4 ES62X-BVA Board Level VF-TLP Test Accessories
4.5 ES62X-BBA Board Level SOA Test Additional Accessories for one channel bias
4.6 ES62X-A2 Wafer Level TLP Setup Essential Test Accessories
4.7 ES62X-WSA Wafer Level Standard TLP Test Accessories
4.8 ES62X-WVA Wafer Level VF-TLP Test Accessories
4.9 ES62X-WBA Wafer Level SOA Test Additional Accessories for one channel bias
4.10 CMPS-200A Compact Manual Probe Station with Trinocular Stereo Microscope

 

(Othe probe stations are available upon request)

External Pulse Module and measurement Options 
 

 

5.1

 

 

ES62X-HBM2

Human Body Model (HBM) 2-pin Pulse Module:
HBM-2: 2kV HBM module, Pairing ES622-20 & ES622-25
HBM-4: 4kV HBM module, Pairing ES622-40 & ES622-50
HBM-8: 8kV HBM module, Pairing ES622-80 & ES622-100
 

 

5.2

 

 

ES62X-HMM2

Human Metal Model (HMM) 2-pin Pulse Module:
HMM-6: 6kV HMM module, Pairing ES622-20 & ES622-25
HMM-12: 12kV HMM module, Pairing ES622-40 & ES622-50
HMM-24: 24kV HMM module, Pairing ES622-80 & ES622-100
5.3 ES62X-MM2 Metal Model (MM) 2-pin Pulse Module:
MM-2: 2kV MM module
5.4 HBM-BA1 HBM Board Level Test Accessories
5.5 MM-BA1 MM Board Level Test Accessories
5.6 TLP based-HMM-BA1 TLP based HMM Board Level Test Accessories
5.7 TLP based-HMM-WA1 TLP based HMM Wafer Level Test Accessories
Leakage or DC IV Measurement Options
6.1 ES62X-SSM System Switch Module (switching between Pulse and DC test)
6.2 ES62X-STP1 SMU Transient Protector
Third Party Equipment Paired with TLP System
7.1 MISC-OSC1 Digital Oscilloscope (1 GHz, 5 Gs, 4 Ch) (Recommended for standard TLP test)
7.2 MISC-OSC6 Digital Oscilloscope (6 GHz, 20 Gs, 4 Ch) (Recommended for VF-TLP test)
7.3 KSMU2401 Keithley 2401, 20V, 1A, 1pA/100nV, 20W, 1 Channel
7.4 KSMU2450 Keithley 2450, 200V, 1A, 10fA/10nV, 20W, 1 Channel
7.5 KSMU2400 Keithley 2400, 20V, 1A, 1pA/100nV, 20W, 1 Channel
7.6 KSMU2410 Keithley 2410, 1100V, 1A, 1pA/100nV, 20W, 1 Channel
7.7 KSMU2602B Keithley 2602B, 40V, 3A, 100fA/100nV, 40W, 2 Channel
7.8 KSMU2635B Keithley 2635B, 200V, 10A, 0.1fA/100nV, 200W, 2 Channel
7.9 KSMUB2902A Keithley B2902A, 210V, 10.5A, 10fA/100nV, 31.8W, 2 Channel
7.10 KPI2230-30-1 Keithley 2230-30-1 3-Channel Programmable DC Power Supply

ES622 Series TLP Pulsed IV-Curve SystemMany customized specifications are available upon request.

 

 
留言詢價

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

C

CODE
關(guān)注我們
  • 聯(lián)系電話:18573116298

  • 聯(lián)系郵箱:billion.xiao@glb-et.com

  • 公司地址:湖南省長沙市天心區(qū)城南路街道芙蓉路與城南路交匯處西北角905房

Copyright © 2025 湖南格雷柏電子科技有限公司版權(quán)所有   備案號:湘ICP備16004312號-3   技術(shù)支持:化工儀器網(wǎng)

sitmap.xml   管理登陸

TEL:18573116298

關(guān)注公眾號
国产无码AV| 搭讪人妻中文字幕系列| 少妇直接网| 艹你| 在线观看亚洲综人网| 韩国大香蕉| 国产黄色三级片| 午夜国产搞基精品| 日人人操人人| 毛片18| 一二三四区无码| 成人亚洲不卡| 亚洲精品偷拍久久| 99久久99久久精品国产片| 9久久国产精品| 无码色亭亭| 尤物在线播放| 蜜臀av免费一区二区三区| 色男人 男人天堂| www.91熟妇| 非洲黑人| 国产中文字幕在线播放| 国产gv免费在线观看| 日韩午夜在线免费视频| 日韩人妻无码一区二区三区99| 亚洲日韩欧美精品激情| 2021美女天天干| 国产ts二区| 亚洲最大激情中文字幕| 色呦呦视频91| www草草影院com| 国产一二视频| 插插插插插插干视频网| japanese精品中国少妇| 国产草莓在线| 91九色在线播放| 日本a√| 久草热久草中文在线视| 国产麻豆一区二区三区精品视频| 水蜜桃av女人天堂| 色哟哟性|